XtendLan S/FTP Cat 6A 15 m sivý; Patch kábel kategórie Cat 6A s dvoma konektormi RJ-45, na prepájanie sieťových zariadení. Dĺžka kábla je 15 m. ZÁKLADNÁ ŠPECIFIKÁCIA; Kategória: Cat 6A...
CPU 2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors,
Dual Socket LGA-3647 (Socket P) supported, CPU TDP support Up to 205W TDP, 2 UPI up to 10.4 GT/s
Note BIOS version 3.2 or above is required to support 2nd Gen Intel® Xeon® Scalable processors (codenamed Cascade Lake-R)
System Memory
Memory Capacity Up to 3TB 3DS ECC RDIMM, DDR4-2933MHz; Up to 3TB 3DS ECC LRDIMM, DDR4-2933MHz, in 12 DIMM slots;
Up to 2TB Intel® Optane™ DC Persistent Memory in memory mode (Cascade Lake only).
Memory Type 2933/2666/2400/2133MHz ECC DDR4 RDIMM, LRDIMM
SATA Intel® C622 controller for 14 SATA3 (6 Gbps) ports; RAID 0,1,5,10
IPMI ASPEED AST2500
Network Controllers Dual LAN with 10Gbase-T
from C622
Graphics Aspeed AST2500 BMC
Input / Output
LAN 2 RJ45 10GBase-T ports
USB 6 USB 3.0 ports (4 rear + 2 via headers)
Video Output 1 VGA port
TPM 1 TPM Header
Expansion Slots
PCI-E 1 PCI-E 3.0 x32 Left Riser Slot,
1 PCI-E 3.0 x16 Right Riser Slot,
1 PCI-E 3.0 x16 for Add-On-Module (AOM)
(Both CPUs need to be installed for full access to PCI-E slots and onboard controllers. See manual block diagram and AOC Support for details.)
Voltage +1.8V, +12V, +3.3V, +5V, +5V standby, Memory Voltages, Monitors CPU voltages
FAN 6x 4-pin fan headers (up to 6 fans), 6 fans with tachometer status monitoring, PWM fan speed control, Status monitoring for speed control
Temperature CPU thermal trip support, Monitoring for CPU and chassis environment
LED CPU / System Overheat LED, UID/Remote UID, BMC/IPMI Heartbeat LED, Power LED
Other Features Chassis intrusion detection, Control of power-on for recovery from AC power loss, CPU thermal trip support for processor protection, Node Manager Support, RoHS, UID
Operating Environment
Operating Temperature Range 10°C - 35°C (50°F - 95°F)
Non-Operating Temperature Range -40°C - 70°C (-40°F - 158°F)
Operating Relative Humidity Range 8% - 90% (non-condensing)
Non-Operating Relative Humidity Range 5% - 95% (non-condensing)
Váš podnet bol odoslaný a bude ho posudzovať moderátor.
Váš podnet nie je možné odoslať
Napíšte svoju recenziu
Skontrolovať pred odoslaním
Váš komentár bol pridaný!
Vašu recenziu nie je možné odoslať
História ceny DEMO
Naša cenotvorba sa zakaždým riadi zásadami férovej ceny. Nehýbeme umelo cenami a nechvastáme sa prestrelenými percentami. Pri každom produkte vždy nájdete históriu ceny.