XtendLan S/FTP Cat 6A 15 m sivý; Patch kábel kategórie Cat 6A s dvoma konektormi RJ-45, na prepájanie sieťových zariadení. Dĺžka kábla je 15 m. ZÁKLADNÁ ŠPECIFIKÁCIA; Kategória: Cat 6A...
Ubiquiti TC-CON; Tienený konektor RJ-45 8p8c. Pre vodič drôt, okrúhly kábel. Bez vložky. Najvyšší podporovaný protokol je 1000BASE-T. Kontakty sú pokryté 50 µm zlata. ZÁKLADNÁ ŠPECIFIKÁCIA;...
Obrotová kieseň pre pevný disk Dell s káblom a skrutkou, určená pre počítače Dell Pro Slim/Slim Plus a Pro Max Slim Desktop. Testovaná a schválená spoločnosťou Dell pre plnú kompatibilitu.
CPU 8th/9th Generation Intel® Core?i3/Pentium®/Celeron® Processor, Intel® Xeon® E-2100 Processor, Intel® Xeon® E-2200 Processor.
Single Socket LGA-1151 (Socket H4) supported, CPU TDP support Up to 95W TDP
Cores / Cache 8 cores, 16 threads
Note BIOS version 1.0b or above is required to support Intel® Xeon® E-2200 and 9th Generation Intel® Core? i3/Pentium®/Celeron® Processors
System Memory
Memory Capacity Up to 128GB Unbuffered ECC UDIMM, DDR4-2666MHz, in 4 DIMM slots
Memory Type 2666/2400/2133MHz ECC DDR4 SDRAM 72-bit
DIMM Sizes 4GB, 8GB, 16GB, 32GB
Memory Voltage 1.2V
Error Detection Corrects single-bit errors
On-Board Devices
Chipset Intel® C242
SATA Intel® C242 controller for 6 SATA3 (6 Gbps) ports; RAID 0,1,5,10
IPMI ASPEED AST2500
Network Controllers Quad LAN with Intel® Ethernet Controller I210-AT
Graphics Aspeed AST2500 BMC
Input / Output
SATA 6 SATA3 (6Gbps) port
LAN 4 RJ45 Gigabit Ethernet LAN ports
USB 4 USB 2.0 ports (2 rear + 2 via headers)
5 USB 3.1 ports (2 rears + 2 via headers + 1 Type A)
System Management Software IPMI (Intelligent Platform Management Interface) v1.5 / 2.0 with KVM support
Power Configurations ACPI Power Management
PC Health Monitoring
Voltage +12V, +3.3V, +5V, +5V standby, 6 -fan status, Chassis intrusion header, Chipset Voltage, Memory Voltages, Monitors CPU voltages, Supports system management utility, System level control, VBAT
FAN 6x 4-pin fan headers (up to 6 fans), 6 fans with tachometer status monitoring, Fan speed control, Overheat LED indication, Thermal control tachometer fan connectors
Temperature Monitoring for CPU and chassis environment, CPU thermal trip support, Thermal Monitor 2 (TM2) support, PECI
LED UID/Remote UID, CPU / System Overheat LED
Other Features ACPI power management, Chassis intrusion detection, Chassis intrusion header, Control of power-on for recovery from AC power loss, CPU thermal trip support for processor protection, Dual Cooling Zones, M.2 NGFF connector, UID, WOL
Operating Environment
Operating Temperature Range 0°C ~ 50°C (32°F ~ 122°F)
Non-Operating Temperature Range -40°C - 70°C (-40°F - 158°F)
Operating Relative Humidity Range 8% - 90% (non-condensing)
Non-Operating Relative Humidity Range 5% - 95% (non-condensing)